    photos/101_0545.jpg

    Racoon in attic

    Inspections
  • Inspections

    photos/DSCN2264.jpg

    Shingles have outlived their usefulness

    Inspections
  • Inspections

    photos/DSCN0115.jpg

    This is where the external ground wire should be attached to Pool Pump Motor.

    Inspections
  • Inspections

    photos/DSCN0114.jpg

    Broken off external grounding wire, that should be attached to Pool Pump Motor, at grounding lug. (this could cause electrical shock)

    Inspections
  • Inspections

    photos/105_1798.jpg

    Evidence of previous fire damage in attic. Buyer was unaware of this.

    Inspections
  • Inspections

    photos/105_1810.jpg

    Improperly flashed chimney could cause water penetration into attic and onto interior ceilings. (should have step flashing and cap flashing)

    Inspections
  • Inspections

    photos/DSCN0304.jpg

    20 amp. Breaker is double lugged (two wires installed on one breaker) this can cause overloading of the breaker.

    Inspections
  • Inspections

    photos/DSCN2883.jpg

    Water Heater missing 3/4 inch discharge pipe at temperature and pressure relief valve, if this valve were to open, house could flood

    Inspections
  • Inspections

    photos/DSCN2867.jpg

    Improper electrical wire junction (should be in an enclosed junction box with cover lid)

    Inspections
  • Inspections

    photos/DSCN3058.jpg

    Seller tried to hide large gap where chimney has pulled away from house.

    Inspections
  • Inspections

    photos/DSCN3076.jpg

    Chimney and Chimney flashing pulling away from house at roof.